Re: Sundance FLO error - 2000 Altamar
Posted By: n1oty In Response To: Re: Sundance FLO error - 2000 Altamar (brad)
Date: Saturday, 24 June 2006, at 7:50 p.m.
The switch is definitely bad. The ohms reading is too resistive.
John
: I assuming I did this correctly, with the
: recirc pump on, I tested for continuity on
: the flow switch at the board, and I got
: between 122-125 ohms fluctuating. I guess
: I'm off to the SPA Store Monday w/ $64 so I
: can hopefully get it heating again! John,
: Thanks again for the additional help on
: this, I was smart enough to figure out where
: the problem was but the specifics I needed
: help on. I'll post back on Monday and let
: you know how it goes. :) Brad
| |