Re: Jac Sn error...
Posted By: n1oty In Response To: Jac Sn error... (cheapjac)
Date: Wednesday, 17 May 2006, at 4:28 a.m.
You either have a bad sensor or bad board. The heater that leaked was caused by poor water chemistry, not dissimilar metals.
John
: HI,
: I have a Jaccuzzi model #S710980 Name: Z112 SPA
: manufacture date of 01/02/01
: The control panel has model S826 (Balboa
: Instruments)
: I replaced the motor and the heater pressure
: switch ~9mos ago
: When you first power up the spa it displays a
: zero. there is a buzzing noise from one of
: the relays, I believe it was the large one
: (possibly a motor start up relay. then the
: code Sn is displyed and the buzzing stops.
: This is very weird , everything was fine until
: I changed the H2O, then it decided to fault
: out...
: The motor doesn't even try to turn over.: When the old one was dying it would trip the
: breaker (it's just a 110V unit)
: Also the old motor died beacuse the galvanized
: pressure switch Jaccuzzi installed into
: a(guess they didn't know about corrosion
: w/dissimilar metals back in 2001..hehehe)
: stainless steel heater had corrorded out and
: leak onto the motor, my replacement switch
: is 100% plastic...
| |
Hot Tub and Spa Cover message Board is maintained by Spa Cover administrator with WebBoard 5.12.
Roll Covers |
Insulating Spa Covers |
Aluminum Hot Tub Covers |
Soft-Top
Floating Spa Blankets |
Spa Cover Lifters |
Spa Covers Accessories
How to Measure for a New Spa Cover |
Cover & Spa Care Info |
Spa Cover Store
FAQ |
About/Contact |
Privacy Policy

Hot Tub & Spa Covers
Abracadabra Hot Tub & Spa Covers
A division of Roberts Hot Tubs
2343 Welcome Ave.
Richmond, CA 94804
(510) 234-7920